CVE-2025-54863Radiometrics VizAir is vulnerable to exposure of the system's REST API key through a publicly accessible configuration file. This allows attackers to remotely alter weather data and configurations, automate attacks against multiple instances, and extract sensitive meteorological data, which could potentially compromise airport operations. Additionally, attackers could flood the system with false alerts, leading to a denial-of-service condition and significant disruption to airport operations. Unauthorized remote control over aviation weather monitoring and data manipulation could result in incorrect flight planning and hazardous takeoff and landing conditions.
CVE-2025-49752Azure Bastion Elevation of Privilege Vulnerability
CVE-2024-12799Уязвимость недостаточно защищенных учетных данных в OpenText Identity Manager Advanced Edition на Windows, Linux,
64 бит позволяет злоупотребление привилегиями. Эта уязвимость может позволить аутентифицированному пользователю получить конфиденциальную информацию более привилегированного пользователя через специально подготовленный полезный груз.
Эта проблема затрагивает Identity Manager Advanced
Edition: с 4.8.0.0 до 4.8.7.0102, 4.9.0.0.
CVE-2025-0867Обычный пользователь использует функцию запуска как для запуска приложений MEAC с административными привилегиями. Для обеспечения автоматического запуска системы учетные данные администратора были сохранены. В результате пользователь EPC2 может выполнять любые команды с административными привилегиями. Это позволяет повысить привилегии до уровня администратора.
CVE-2021-36783Уязвимость, связанная с недостаточно защищенными учетными данными в SUSE Rancher, позволяет аутентифицированным владельцам кластеров, членам кластеров, владельцам проектов и членам проектов читать учетные данные, пароли и токены API, которые были сохранены в виде открытого текста и предоставлены через конечные точки API. Эта проблема затрагивает: SUSE Rancher Rancher версии до 2.6.4; Rancher версии до 2.5.13.
CVE-2019-1384Существует уязвимость обхода функции безопасности, при которой сообщение NETLOGON может получить ключ сеанса и подписывать сообщения. Чтобы воспользоваться этой уязвимостью, злоумышленник может отправить специально созданный запрос аутентификации, также известная как «Уязвимость обхода функции безопасности Microsoft Windows».
CVE-2025-67135Weak Security in the PF-50 1.2 keyfob of PGST PG107 Alarm System 1.25.05.hf allows attackers to compromise access control via a code replay attack.
CVE-2025-65552D3D Wi-Fi Home Security System ZX-G12 v2.1.1 is vulnerable to RF replay attacks on the 433 MHz sensor communication channel. The system does not implement rolling codes, message authentication, or anti-replay protection, allowing an attacker within RF range to record valid alarm/control frames and replay them to trigger false alarms.
CVE-2025-55306GenX_FX is an advance IA trading platform that will focus on forex trading. A vulnerability was identified in the GenX FX backend where API keys and authentication tokens may be exposed if environment variables are misconfigured. Unauthorized users could gain access to cloud resources (Google Cloud, Firebase, GitHub, etc.).
CVE-2025-54428RevelaCode is an AI-powered faith-tech project that decodes biblical verses, prophecies and global events into accessible language. In versions below 1.0.1, a valid MongoDB Atlas URI with embedded username and password was accidentally committed to the public repository. This could allow unauthorized access to production or staging databases, potentially leading to data exfiltration, modification, or deletion. This is fixed in version 1.0.1. Workarounds include: immediately rotating credentials for the exposed database user, using a secret manager (like Vault, Doppler, AWS Secrets Manager, etc.) instead of storing secrets directly in code, or auditing recent access logs for suspicious activity.
CVE-2025-52095An issue in PDQ Smart Deploy V.3.0.2040 allows an attacker to escalate privileges via the Credential encryption routines in SDCommon.dll
CVE-2025-27650Vasion Print (ранее PrinterLogic) до версии Virtual Appliance Host 22.0.862 Application 20.0.2014 позволяет частные ключи в Docker Overlay V-2023-013.
CVE-2025-27648Vasion Print (ранее PrinterLogic) до Virtual Appliance Host 22.0.913 приложение 20.0.2253 позволяет раскрытие паролей между тенантами V-2024-003.
CVE-2025-25570Vue Vben Admin 2.10.1 позволяет несанкционированный доступ к бэкэнду из-за проблемы с жестко закодированными учетными данными.
CVE-2025-23342Инструмент NVIDIA NVDebug содержит уязвимость, которая может позволить злоумышленнику получить доступ к привилегированной учетной записи. Успешная эксплуатация этой уязвимости может привести к выполнению кода, отказу в обслуживании, повышению привилегий, раскрытию информации и нарушению целостности данных [1].
Источники:
- [1] https://nvidia.custhelp.com/app/answers/detail/a_id/5696