CVE-2018-10594

Scores

EPSS

0.788medium78.8%
0%20%40%60%80%100%

Percentile: 78.8%

CVSS

9.8critical3.x
0246810

CVSS Score: 9.8/10

All CVSS Scores

CVSS 3.x
9.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS 2.0
7.5

Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P

Description

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Scaner-VS 7 — a modern vulnerability management solution

Uses this database for vulnerability detection. High-speed search, cross-platform, advanced configuration audit, and flexible filtering. Suitable for organizations of any size.
Learn more about Scaner-VS 7

Sources

nvd

CWEs

CWE-121

Exploits

Exploit ID: 44965

Source: exploitdb

URL: https://www.exploit-db.com/exploits/44965

Exploit ID: 45574

Source: exploitdb

URL: https://www.exploit-db.com/exploits/45574

Vulnerable Software (1)

Type: Configuration

Vendor: deltaww

Product: commgr

Operating System: * * *

Trait:
{  "children": [    {      "cpe_match": [        {          "cpe23uri": "cpe:2.3:a:deltaww:commgr:*:*:*:*:*:*:*:*",          "versionEndIncluding": "1.08",          "vulnerable": true        }...

Source: nvd