Webaccess Scada
Vulnerabilities
42
Known exploited
0
Max CVSS
9.8
Top EPSS
0.05754
Severity breakdown
Critical
11
High
18
Medium
13
Low
0
Affected version ranges
9.1.5u–9.1.6< 8.2_20170817< 8.3.1< 8.4.5< 9.0.1< 9.1.4< 9.2.2≤ 9.0≤ 9.0.1≤ 9.0.3≤ 9.1.3
Also matched as (raw): webaccess/scada,webaccess_scada
Top vulnerabilities
CVE-2023-32628
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.
CVE-2023-32540
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.
CVE-2023-1437All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
CVE-2021-32943The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
CVE-2019-6523WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
CVE-2019-6519WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
CVE-2018-8845In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code.
CVE-2018-7505In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a TFTP application has unrestricted file uploads to the web application without authorization, which may allow an attacker to execute arbitrary code.
CVE-2018-7499In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several stack-based buffer overflow vulnerabilities have been identified, which may allow an attacker to execute arbitrary code.
CVE-2018-7497In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several untrusted pointer dereference vulnerabilities have been identified, which may allow an attacker to execute arbitrary code.
CVE-2018-10589In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to execute arbitrary code.
CVE-2021-22669Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.
CVE-2020-25161The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
CVE-2020-13555An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
CVE-2020-13553An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
CVE-2020-13552An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
CVE-2020-13551An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
CVE-2025-14849Advantech WebAccess/SCADA
is vulnerable to unrestricted file upload, which may allow an attacker to remotely execute arbitrary code.
CVE-2019-6521WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
CVE-2020-13554An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
CVE-2018-8841In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user.
CVE-2020-13550A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability.
CVE-2018-7503In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to disclose sensitive information on the target.
CVE-2018-7501In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several SQL injection vulnerabilities have been identified, which may allow an attacker to disclose sensitive information from the host.
CVE-2018-7495In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an external control of file name or path vulnerability has been identified, which may allow an attacker to delete files.