V
Scaner-VS
HomeCatalogSourcesCWECAPECATT&CKMitigationsProductsVendorsDocs
← Back to List
bdu,nvd

Automationdirect

Vulnerabilities
61
Known exploited
0
Critical
17
High
41

Top vulnerabilities

BDU:2025-05638Уязвимость веб-сервера микропрограммного обеспечения шлюза Modbus AutomationDirect MB-Gateway связана с отсутствием механизма аутентификации для критически важной функции. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, получить несанкционированный доступ к устройству
CVE-2024-24963A stack-based buffer overflow vulnerability exists in the Programming Software Connection FileSelect functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to stack-based buffer overflow. An attacker can send an unauthenticated packet to trigger this vulnerability.This CVE tracks the stack-based buffer overflow that occurs at offset `0xb6e84` of v1.2.10.9 of the P3-550E firmware.
CVE-2024-24962A stack-based buffer overflow vulnerability exists in the Programming Software Connection FileSelect functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to stack-based buffer overflow. An attacker can send an unauthenticated packet to trigger this vulnerability.This CVE tracks the stack-based buffer overflow that occurs at offset `0xb6e98` of v1.2.10.9 of the P3-550E firmware.
CVE-2024-23601A code injection vulnerability exists in the scan_lib.bin functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted scan_lib.bin can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.
CVE-2024-21785A leftover debug code vulnerability exists in the Telnet Diagnostic Interface functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted series of network requests can lead to unauthorized access. An attacker can send a sequence of requests to trigger this vulnerability.
CVE-2021-32986After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly.
CVE-2021-32984All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.
CVE-2021-32980Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.
CVE-2020-6969It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
CVE-2020-10921This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
CVE-2020-10920This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
BDU:2024-05901Уязвимость библиотеки scan_lib.bin микропрограммного обеспечения программируемых логических контроллеров AutomationDirect P3-550E связана с недостаточной проверкой подлинности данных. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, выполнить произвольный код или вызвать отказ в обслуживании
BDU:2024-05900Уязвимость микропрограммного обеспечения программируемых логических контроллеров AutomationDirect P3-550E связана с недостаточной защитой служебных данных при реализации кода отладки. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, выполнить произвольный код или вызвать отказ в обслуживании
BDU:2024-05617Уязвимость микропрограммного обеспечения программируемых логических контроллеров AutomationDirect P3-550E связана с переполнением буфера в стеке. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, выполнить произвольный код
CVE-2024-22187A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability.
CVE-2022-2003AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
BDU:2024-05898Уязвимость компонента Software Connection Remote Memory Diagnostics микропрограммного обеспечения программируемых логических контроллеров AutomationDirect P3-550E связана с недостатками контроля доступа. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, выполнить произвольный код или вызвать отказ в обслуживании
CVE-2024-24959Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb6c18`.
CVE-2024-24958Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb6bdc`.
CVE-2024-24957Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb6aa4`.
CVE-2024-24956Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb6a38`.
CVE-2024-24955Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb69fc`.
CVE-2024-24954Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. Specially crafted network packets can lead to heap-based memory corruption. An attacker can send malicious packets to trigger these vulnerabilities.This CVE tracks the arbitrary null-byte write vulnerability located in firmware 1.2.10.9 of the P3-550E at offset `0xb69c8`.
CVE-2024-24947A heap-based buffer overflow vulnerability exists in the Programming Software Connection CurrDir functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to denial of service. An attacker can send an unauthenticated packet to trigger these vulnerability.This CVE tracks the heap corruption that occurs at offset `0xb68c4` of version 1.2.10.9 of the P3-550E firmware, which occurs when a call to `memset` relies on an attacker-controlled length value and corrupts any trailing heap allocations.
CVE-2024-24946A heap-based buffer overflow vulnerability exists in the Programming Software Connection CurrDir functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to denial of service. An attacker can send an unauthenticated packet to trigger these vulnerability.This CVE tracks the heap corruption that occurs at offset `0xb686c` of version 1.2.10.9 of the P3-550E firmware, which occurs when a call to `memset` relies on an attacker-controlled length value and corrupts any trailing heap allocations.
Open in catalog with vendor filter →