Sinamics S120

Vulnerabilities
13
Known exploited
0
Max CVSS
10
Top EPSS
0.03315

Severity breakdown

Critical
1
High
11
Medium
1
Low
0
Also matched as (raw): sinamics_s150,sinamics_s/g_family_firmware,sinamics_g110d,sinamics_g120,sinamics_g150,sinamics_g120c,sinamics_g120d,sinamics_g130,sinamics_s120_firmware,sinamics s120,sinamics_g180,sinamics_s120cm

Top vulnerabilities

CVE-2013-6920Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
CVE-2017-12741Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
CVE-2022-47375A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
CVE-2022-47374A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
CVE-2019-6568The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CVE-2019-10936Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
CVE-2019-10923An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
BDU:2019-04219Уязвимость программно-аппаратного обеспечения Siemens связана с ошибками обработки большого количества UDP-пакетов. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, вызвать отказ в обслуживании
BDU:2019-04211Уязвимость программно-аппаратных средств Siemens связана с возможностью нарушения синхронизации времени (IRT). Эксплуатация уязвимости может позволить нарушителю, действующему удалённо, вызвать отказ в обслуживании
BDU:2019-01782Уязвимость веб-сервера программно-аппаратного обеспечения Siemens связана с недостаточной проверкой вводимых данных. Эксплуатация уязвимости может позволить нарушителю, действующему удаленно, вызвать отказ в обслуживании
CVE-2017-2681Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
CVE-2017-2680Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
BDU:2022-04330Уязвимость служб TCP программно-аппаратного обеспечения Siemens связана с неконтролируемым расходом ресурсов. Эксплуатация уязвимости может позволить нарушителю, действующему удалённо, вызвать отказ в обслуживании